Humboldt HM-3000.3F Digital MasterLoader Manual de usuario

Busca en linea o descarga Manual de usuario para Equipo Humboldt HM-3000.3F Digital MasterLoader. Humboldt HM-3000.3F Digital MasterLoader User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Digital MasterLoader

product manual07.08 HM-3000.3FHumboldt Digital MasterLoader

Pagina 2 - TABLE OF CONTENTS

Computer ConnectionSingle Device ConnectionTheHM-3000canbeconnectedtoaPCcomputertotakeadvantageofHumboldt’s HMTS software capabilities, c

Pagina 3 - ©2005 Humboldt Mfg. Co

Figure 7. Rear panel of HM-3000 showing Analogue Port, RS-232 Port, RS-485 Input and Output and the four instrumentation channel inputs.Multi Device

Pagina 4 - Introduction

Figure 8. Diagram illustrating computer and multiple device connections.CAT 5 CableRS-232 to RS-485 converter(HM-000375)Figure 9. Back Panel electro

Pagina 5 - General Warnings

OperationPower SwitchThePowerSwitchislocatedinthebackpanelontherearofthemachineabove the electrical cord inlet. Also, located between

Pagina 6

Set Up KeyPushingtheSetUpKeybringsupthemainsetupscreenfrom which you can run a test, review your last test, access the engineering set up

Pagina 7 - Quick Start Guide

Set-up FunctionsSet DateTo set the Date press until you see this screen: Press you will see this screen:Press you will see this screen: P

Pagina 8 - Installation and Set-up

13Set TimeTo set the Time press until you see this screen: Press you will see this screen: Press you will see this screen: Press

Pagina 9 - Pin4= –dc Output

14Set UnitsTo set the Units the HM-3000 will use to display results, press until you see this screen: Press you will see this screen: Press

Pagina 10 - Computer Connection

15 Press you will see this screen: Press you will see this screen: Press(DATE/UNIT/STANDARD).Youshouldseethisscreen:Press(

Pagina 11 - ANALOG PORT ACCESS

16Press(SPEED)tomovebetweenthenumbers.Keeppressing untilthedigityouwanttochangeisashing.Onceyouhaveselectedthe number you

Pagina 12 - (HM-000375)

TABLE OF CONTENTSIntroduction ... 1ApplicationsProduct UseProd

Pagina 13 - Operation

17Channel ConfigurationIf you are adding new instrumentation, changing existing instrumentation or reconfiguring the HM-3000’s channel setup, you need t

Pagina 14

Press (INCREASE)or (DECREASE) repeatably to scroll through the available channel names for an appropriate choice. Choices for channel namesar

Pagina 15 - Set-up Functions

19Press(SENSORMAX)tomovebetweenthenumbers.Keeppressinguntilthedigityouwanttochangeisashing.Onceyouhaveselected the number yo

Pagina 16

20To assign a test to the selected channel, press the corresponding function keytothetestyouwishtoselect.Pressingakeywilltogglebetween“Y

Pagina 17

CalibrationThis menu item is used to calibrate or verify the calibration of the HM-3000.WARNING: Calibration should only be performed by trained perso

Pagina 18

22Press(SELECTCHANNEL)toscrollthroughandchoosethechannelyou wish to calibrate. Once you have chosen the desired channel you wish to calibr

Pagina 19

Humboldt Calibration Instrumentation Chart23 Load Cell Part# English Gain Metric Gain (divisions) (divisions) 10,000 lb. (50kN) HM

Pagina 20

24* RECALL CALIBRATION* CHANGE DEVICE ID* DATE/UNIT/STANDARD* MANUFACTURES INFOPress (CHANGEDEVICEID).Youshouldseethisscreen: Press

Pagina 21

25Press(RUNTEST)Youshouldseethisscreen:Press (CBR/LBR TEST) You should see this screen:Press (SPEED)toaccessthespeedreadouton

Pagina 22

26NOTE:Ifyouapplyallthesurchargeweightinthemoldatthebeginning ofthetest,justPress to continue. The HM-3000 will start the test.

Pagina 23

©2005 Humboldt Mfg. Co.Channel Configuration ... 17Naming Channel ...

Pagina 24 - Calibration

27Press(RUNTEST)Youshouldseethisscreen:Press (MARSHALL TEST) This will automatically start the platen to rise at a rate of 2.0 in/min

Pagina 25 - * SET SENSOR MAX 12345

28Peakvaluesareshownonthersttwolines.Toreviewallthedata, press (REVIEWDATA).Youshouldseethisscreen: Pressing (PRINT

Pagina 26 - Device ID

29Press You should see this screen: Press (RUNTEST)Youshouldseethisscreen:Press(USERDEFINEDTEST).Youshouldseethisscreen:Press

Pagina 27 - Standard Tests

30Once the load cell has reached its peak load and fallen 2%, the HM-3000 will stop collecting data and reverse the platen to its down position at the

Pagina 28

31SOIL-CEMENTSee User-Defined Unconfined Compression, without the displacement transducer selected in the test configurationTSRSee User-Defined Unconfined

Pagina 29

32SoftwareThe HM-3000 comes with Humboldt’s HMTS data collection software. This software can be used to collect data from tests by creating user-defin

Pagina 30

33SpecificationsApplicable StandardsCovers: CBR, UU, CU, CD, UC, Marshall and Hveem TestsASTM: D1883, D2850, D2166, D4767 and D5581 and D6927AASHTO: T1

Pagina 31

34Test AccessoriesHM-3001—CaliforniaBearingRatio(CBR)AccessorySet:HM-2300.100 Loadcell10,000lb.(50kN)HM-2310.10 DisplacementTransducer1.

Pagina 32

35SupportPhonesupportisavailableforgeneraloperatingquestionsandtroubleshootingproblemsbetween8amand5pmEasternTime.Pleasecall:1.800

Pagina 33

36NOTES

Pagina 34

IntroductionApplicationsThe HM-3000 Series MasterLoader Compression Testing Frame is designed for applications requiring multi-purpose loading systems

Pagina 35 - Software

www.humboldtmfg.comHUMBOLDTTesting Equipment forConstruction MaterialsHumboldt Mfg. Co.875 Tollgate RoadElgin, Illinois 60123 U.S.A.U.S.A. Toll Free:

Pagina 36 - Specifications

• PlugandplaySerialport(RS232)communicationswithHumboldtMaterial Testing Software (HMTS) for controlling and downloading stored data.• Uniq

Pagina 37 - Test Accessories

The programmable, read-only memory, integrated circuit package contained in this equipment and covered with a copyright notice label contains propriet

Pagina 38 - Hidden Functions

1Quick Start GuideStartup ScenariosIf your HM-3000 was purchased with instrumentation for one specific test: the instrumentation has been installed and

Pagina 39

Installation and Set-upUnpackingInitial inspection should include checking for physical damage during shipping and obvious external damage to the prod

Pagina 40 - HUMBOLDT

If you are using third-party cables for load cells/transducers connections, make sure they are wired to be compatible with the HM-3000. Consult Figur

Comentarios a estos manuales

Sin comentarios